G. S. Medilinks
G. S. Medilinks
Vidhyadhar Nagar, Jaipur, Rajasthan
GST No. 08AHXPR1523K1ZQ
Send E-mail
Call 0804603778984% Response Rate

Pulse Oximeter


Importer of a wide range of products which include tabletop pulse oximeter and cms70a tabletop pulse oximeter.

REQUEST CALLBACK
Get Best Quote

Approx. Rs 18,000 / Unit Get Latest Price

Product Brochure
Product Details:
Usage/ApplicationClinic
ParametersNIBP+SPO2
Display TypeDual Color OLED Display
Operating TemperatureN.A.
SPO2 Measurement Range80% - 100%
Weight3 kg
Display Mode3 DISPLAY MODES
Continuous Working Time18 hours

Features:

  • Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance
  • Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics
  • Built-in rechargeable Li-polymer battery for uninterrupted monitoring
  • Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor (in ambulance) monitoring
  • With user-friendly interface
  • Display with 2.8” (320×240) color TFT LCD and red and yellow highlight LED
  • Visual and audible alarm for Systolic Pressure (SYS), Diastolic Pressure (DIA), Mean Pressure (MAP), SpO2 and Pulse rate (PR) and upper and lower limit of alarm can be set
  • Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data
  • Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate (PR) trend graph within 20-hour

 

NIBP monitoring:

  • Measurement method: Oscillometry
  • Measurement mode: manual/auto/continuous
  • Auto measurement interval: adjustable from 1 to 90 minutes
  • Resolution: 1mmHg
  • Accuracy: Maximum Mean deviation ≤±5mmHg, Maximum Standard deviation ≤8mmHg
  • Self-check function
  • Overpressure protection: double protection for software and hardware

 

Range

  • Systolic pressure: 40mmHg~270mmHg
  • Mean pressure: 20mmHg~235mmHg
  • Diastolic Pressure: 10mmHg~215mmHg

 

Pediatric:

  • Systolic pressure: 40mmHg~200mmHg
  • Mean pressure: 20mmHg~165mmHg
  • Diastolic Pressure: 10mmHg~150mmHg

 

Neonatal:

  • Systolic pressure: 40mmHg~135mmHg
  • Mean pressure: 20mmHg~110mmHg
  • Diastolic Pressure: 10mmHg~100mmHg
  • Upper and lower limit of alarm

 

Adult:

  • Systolic pressure: 40mmHg~270mmHg
  • Mean pressure: 20mmHg~235mmHg
  • Diastolic Pressure: 10mmHg~215mmHg

 

Pediatric:

  • Systolic pressure: 40mmHg~200mmHg
  • Mean pressure: 20mmHg~165mmHg
  • Diastolic Pressure: 10mmHg~150mmHg

 

Neonatal:

  • Systolic pressure: 40mmHg~135mmHg
  • Mean pressure: 20mmHg~110mmHg
  • Diastolic Pressure: 10mmHg~100mmHg

Yes! I am Interested


Get Best Quote

Approx. Rs 15,500 / 1 PIC Get Latest Price

Product Details:
Parameter MeasuresSpO2 + Pulse Rate
TypePhotoelectric Oxyhemoglobin Inspection
BrandContec
Usage/ApplicationHospital
Model Name/NumberCMS70A
FeaturesDigital, Portable


Principle of the CMS70A Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.

Yes! I am Interested


 






Corporate Brochure




Explore More Products
 

 

Send SMS
Gaurav Rawat  (Proprietor)
G. S. Medilinks
S-7, Dwarika Tower, Central Spine Vidhyadhar Nagar
Jaipur - 302039 , Rajasthan , India
Send E-mail
Share Us:
X