Bedside Monitors


Prominent & Leading Importer from Jaipur, we offer bedside monitor cms8000, multipara monitor cms9200 and two para monitor.

REQUEST CALLBACK
  • +1
Get Best Quote

Approx. Rs 38,000 / Unit Get Latest Price

Product Details:
Minimum Order Quantity1 Unit
Parameters7 Para
Warm Up TimeN.A.
Charging TimeN.A.
Operating TemperatureN.A.
UsageClinic, Hospital
ModelCMS8000
BrandContec
DisplayDigital

NIBP:

  • Method: Oscillometry
  • Modes: Manual/Auto/Continuous
  • Auto measure time: Adjustable
  • Measurement rang: 10-270mmHg

 

ECG:

  • Lead mode: 3-lead or 5-lead
  • Lead selection: I, II, III, avR, avL, avF and V
  • Heart rate range: Adult: 15-300bpm: Pediatric/Neonatal: 15-300bpm
  • ECG waveform: 2 channels
  • Accuracy: ± 1 bpm or ±1%
  • S-T segment detection Measurement rang: -0.2mv~2.0mv
  • Alarm: Yes, audible and visual alarm, alarm events review
  • High resolution 12.1″color TFT display
  • Light weight, compact and portable
  • ECG, APO2, NIBP, RESP, 2-TEMP, PR
  • Optional: 2-IBP, ETCO2 and thermal printer
  • Built-in rechargeable lithium battery
  • ECG waveforms of 7-leads display on the same screen
  • 72-hours graphic and tabular trends of all parameters
  • 72 alarm events of all parameters recall
  • 32 seconds full-disclosure waveform review
  • 500 NIBP measurement date can be storage and recall
  • Date and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Suitable for adult, pediatric and neonatal patient

 

SPO2:

  • Measurement range: 0-100%
  • Accuracy: 70-100%, ±2% 0-69%, unspecified

 

Pulse Rate:

  • Range: 20-254bpm
  • Accuracy: ±3bpm

 

Respiration:

  • Method: RA-LL impedance
  • Range: Adult: 0-120rpm; pediatric/neonatal: 0-150rpm
  • Apnea alarm: Yes

 

Temperature:

  • Range: 0-50℃
  • Apnea: 0.1℃
  • Channel: Dual-Channel


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Jaipur
  • Delivery Time: 1-7 Days
  • Packaging Details: Carton Packing

Yes! I am Interested
View PDF


REQUEST CALLBACK
  • +2
Get Best Quote

Approx. Rs 48,000 / Unit Get Latest Price

Product Details:
Minimum Order Quantity1 Unit
NIBP Measurement range10-300mmHg
SPO2 Measurement Range0-100%
Pulse Rate Range20-254bpm
Parameters5 para
ECG Lead Mode12 lead
Heart Rate Range15-380 bpm
UsageClinical Use, Hospital, Clinic, Hospitals, Emergency Transport Vehicles
Suitable ForAdult, Neonatal, Pediatric
NIBP ModeManual, Continuous, Auto
ECG Lead Selection1, 2
ECG Waveform3 Channels
Respiration RangeN.A.
FrequencyN.A.
Power SourceBattery Operated
ResolutionLED
Voltage220V
BatteryLithium
ModelCMS9200
BrandCONTEC
DisplayDigital

Product Details:

Lead Selections aVF
Parameters NIBP
Screen Size 12
Display Type LCD
Power Source Electricity
Voltage 220 V
Features Spo2 , NIBP , Pulse Rate, Respiration, ECG & Temp
Suitable for Adult, Pediatric, Infant, Neonatal
Measurement Site Upper Arm
Resolution High Resolution
Pixel Pitch 800x480


This Five Parameter Monitor (5 Para) is conventional equipment that finds its application in Arrhythmia analysis and S-T segment analysis ensuring high level of accuracy. This ensures the ECG waveforms of 7-leads display on the same screen. Multipara Patient Monitor suitable for adult, paediatric and neonatal patient this equipment is net-workable with central monitoring system.

Features:

  • High resolution 12.1” color TFT display
  • Lightweight, compact and portable
  • ECG, SPO2, NIBP, RESP, 2-TEMP PR
  • 32 second full disclosure waveform review
  • 500 NIBP measurement data can be storage and recall
  • Data and waveforms color be adjustable
  • Optional 2-IBP, ETCO2, and thermal printer
  • Built-in rechargeable lithium battery
  • ECG waveforms of 7-leads display on the same screen
  • 72 hours graphic and tabular trends of all parameters
  • 72 alarm events of all parameters recall
  • Arrhythmia analysis and S-T segment analysis


Specifications:

  • Measurement range: 0-100%
  • Accuracy: ± 2 digit (70 – 100% ); 0-69% unspecified
  • Display: 8.4” Colour TFT Display
  • Sweep Speed: 12.5 mm/s, 25 mm/s, 50 mm/s


Standard configuration:

  • ECG, NIBP, SPO2
  • Audible and visual alarms with adjustable alarm ranges
  • Net-workable with central monitoring system
  • Suitable for adult paediatric and neonatal patient
  • Basic parameters (ECG, SPO2, NIBP) in a durable case for bedside monitoring and transport monitoring
  • Powerful data management and storage capacity


NIBP:

  • Operation models manual / automatic / STAT
  • Method oscillometry
  • Measurement unit mm Hg / K Pa selectable
  • Over pressure protection provided
  • Measurement types systolic, diastolic, mean


ECG:

  • Alarm events recallable
  • S-T detection YES, Arrhythmia analysis available
  • Accuracy: ± 1 bpm or ± 1%, which is greater
  • Lead type 5-lead
  • Input RA, LA, LL, V
  • Protection withstand 4000 VAC/50 Hz Voltage in isolation against electrosurgical and defibrillation
  • Alarm provided, audible and visual alarm


Optional:

  • Thermal Printer, Pace Maker
  • RESP, 2-TEMP, 2-IBP, ETCO2, Network

 

Request
Callback



Additional Information:

  • Item Code: CMS8000


Additional Information:
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Jaipur
  • Production Capacity: Continous
  • Delivery Time: 1-7 Days
  • Packaging Details: Carton Packing

Yes! I am Interested
View PDF


REQUEST CALLBACK
  • +1
Get Best Quote

Approx. Rs 18,000 / Unit Get Latest Price

Product Details:
Minimum Order Quantity1 Unit
NIBP Measurement range10-300mmHg
SPO2 Measurement Range0-100%
Pulse Rate Range30-250 bpm
ParametersNIBP+SPO2
ECG Lead ModeNO
Heart Rate Range15-300 bpm
UsageClinical Use
ModelCMS5100
BrandContec
Suitable ForNeonatal, Pediatric, Adult
NIBP ModeAuto, Continuous, Manual
ECG Lead SelectionNO
ECG WaveformNO
Respiration RangeN.A.
FrequencyN.A.
Power SourceN.A.
ResolutionN.A.
Voltage220V
BatteryLithium
DisplayDigital
ColorWhite

Features:

  • Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance
  • Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics
  • Built-in rechargeable Li-polymer battery for uninterrupted monitoring
  • Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor (in ambulance) monitoring
  • With user-friendly interface
  • Display with 2.8” (320×240) color TFT LCD and red and yellow highlight LED
  • Visual and audible alarm for Systolic Pressure (SYS), Diastolic Pressure (DIA), Mean Pressure (MAP), SpO2 and Pulse rate (PR) and upper and lower limit of alarm can be set
  • Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data
  • Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate (PR) trend graph within 20-hour

 

Performance:

NIBP monitoring:

  • Measurement method: Oscillometry
  • Measurement mode: manual/auto/continuous
  • Auto measurement interval: adjustable from 1 to 90 minutes
  • Resolution: 1mmHg
  • Accuracy: Maximum Mean deviation ≤±5mmHg, Maximum Standard deviation ≤8mmHg
  • Self-check function
  • Overpressure protection: double protection for software and hardware

 

Range:

  • Systolic pressure: 40mmHg~270mmHg
  • Mean pressure: 20mmHg~235mmHg
  • Diastolic Pressure: 10mmHg~215mmHg

 

Pediatric:

  • Systolic pressure: 40mmHg~200mmHg
  • Mean pressure: 20mmHg~165mmHg
  • Diastolic Pressure: 10mmHg~150mmHg

 

Neonatal:

  • Systolic pressure: 40mmHg~135mmHg
  • Mean pressure: 20mmHg~110mmHg
  • Diastolic Pressure: 10mmHg~100mmHg
  • Upper and lower limit of alarm


Additional Information:
  • Item Code: CMS5100
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Jaipur
  • Production Capacity: Continous
  • Delivery Time: 1-7 Days
  • Packaging Details: Carton Packing

Yes! I am Interested
View PDF


 






Corporate Brochure




 

 

Send SMS
G. S. Medilinks
Gaurav Rawat  (Proprietor)
S-7, Dwarika Tower, Central Spine Vidhyadhar Nagar
Jaipur - 302039 , Rajasthan , India
Send E-mail
Share Us:
X